Measures to deal with unbalanced design of control valve device of pneumatic components
Addtime: 2019/11/1 16:43:13  click: 1028
At the beginning of the design, the control valve of pneumatic components can not find a matching, so it will create the imbalance of the whole system, which will cause unnecessary loss of energy consumption, so it is possible to be perfect at the beginning of the system design.
If the system cannot reach full load due to unbalanced design conditions, the total investment of the entire unit will not be returned. When large loads are required, the pneumatic component control valve is fully open and cannot handle this condition. It is very difficult to determine the size of the two-way control valve, the calculated valve is generally not available in the market, so the size is usually larger. In this way, circulatory system balance becomes very critical. Generally speaking, the input of this part is less than 1% of the total investment of hvac. Every morning, after overnight downtime, full power is needed to restore comfort as quickly as possible. A well-balanced system can be done quickly. If the startup time can be saved by 30 minutes, the energy consumption can be saved by 6% per day, compared with 8 hours of working time. This is more than all the allocated pumping costs.
In variable flow distribution, pumping energy consumption generally accounts for less than 5% of the seasonal consumption of refrigeration units. And the charge that reduces indoor temperature more 1 degree need is 10 to 16%. Therefore, getting the right comfort level is a better way to save energy. Therefore, all measures designed to reduce pumping energy consumption must be taken so that they do not adversely affect the operation of the control loop of the terminal device. By maximizing the design water temperature difference. T and using better positioning Δ p sensor of variable speed pump, can reduce the cost of pumping. Under medium loads, stable adjustable PI control requires less flow than switching control, thus reducing pumping costs.
But more important is the size of the compensation pump. The balance valve provided by the compensation method can display such oversized condition. All overpressure can be found on the balance valve near the pump. After the pump is modified, the pneumatic element balancing valve can be reopened. Cyclic balancing requires the right tools, newer procedures, and effective measuring devices. The pneumatic component manual balancing valve is obviously a more reliable, simpler product to obtain the correct flow under design conditions and is always capable of measuring the flow for diagnosis. It can also be connected to the differential pressure controller if necessary.
This article reprint. If involve tort please contact us to delete.
[Go back to the previous page]
Sales phone: 15189699567
  13511554862
Address: no. 143 changjiang east road, huaiyin district, huaian, China
Email: [email protected]
Alibaba store: https://shmmech.1688.com
Website: http://www.niceng.cn
This website is some pictures from the network, if there are any infringement, please inform us to delete
Web site for the record number: Sue ICP for 2022005973-1
主站蜘蛛池模板: 亚洲欧美一区二区久久 | 欧美一区二区三区精品国产 | 国内久久精品 | 四虎影视在线影院4hu | 97久久免费视频 | 色综合精品久久久久久久 | 欧美成人性视频播放 | 久久99精品久久久久久园产越南 | 波多野结衣视频一区二区 | 国产精品在线观看 | 99国产大尺度福利视频 | 国产精品66 | 国产香蕉视频在线 | 久久综合综合久久97色 | 日韩男人天堂 | 999无色码中文字幕 999小视频 | 日日操夜夜爱 | 国产精品久久久久影院色老大 | 日本xxxx色视频在线观看免 | 国产精品久久毛片蜜月 | 国产精品美女视频 | 欧美日韩视频在线播放 | 成人欧美日韩 | 国产精品久久久久天天影视 | 激情综合色综合啪啪开心 | 免费久久精品国产片香蕉 | 99视频在线国产 | 色香蕉在线| 大尺度福利视频在线观看网址 | a级毛片在线观看 | 性生活免费网站 | 在线国产视频 | 黄频网站在线观看视频 | 97高清国语自产拍中国大陆 | 狠狠色丁香久久综合五月 | 久久亚洲不卡一区二区 | 国产香蕉视频在线观看 | 四虎国产免费 | 五月情视频在线观看 | 久久成人网18网站 | 日韩在线视精品在亚洲 |